CAUTION:
Read and follow all Safety
Rules and Operating Instructions
Before Every Use of this Product.
SAVE THESE INSTRUCTIONS.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
OPERATOR’S MANUAL
Model No.
200.71240
®
00-99-000853/0808
BATTERY CHARGER
50/15/2 Amp,
6/12 Volt,
Manual
250 Amp
ENGINE STARTER
Page view 0
1 2 3 4 5 6 ... 18 19

Summary of Contents

Page 1 - 200.71240

CAUTION:Read and follow all Safety Rules and Operating Instructions Before Every Use of this Product.SAVE THESE INSTRUCTIONS.Sears, Roebuck and Co., H

Page 2 - TABLE OF CONTENTS

• 8 •PRODUCT FEATURES9. In case of charger malfunction, DO NOT attempt to repair charger yourself. To arrange for charger repair, or information about

Page 3

• 9 •Hold axle upright on oor or work surface. Then, using a hammer, tap one 10.2 of the plastic axle caps onto the top end of the axle. Be sure to t

Page 4

• 10 •Place the charger on its side. Place one end of each bracket into slot, then 10.3 place the axle assembly under each bracket. Fasten the other s

Page 5

• 11 •OPERATING INSTRUCTIONS11. Follow steps in section 6 or 7 for hookup and disconnect instructions, and 11.1 precautions. SETTING THE CONTROLSAll

Page 6

• 12 •CALCULATING CHARGE TIME12. The Chart Method12.1 Use the following table to more accurately determine the time it will take to bring a battery to

Page 7

• 13 •The Hydrometer or Electronic Method12.2 To nd the time needed to fully charge your battery, determine the bat-tery’s charge level with a hydrom

Page 8

• 14 •USING THE ENGINE START FEATURE13. Set charge rate switch and timer to OFF positions.13.1 With the charger unplugged from the AC outlet, connect

Page 9 - Grounding Methods

• 15 •TROUBLESHOOTING16. PROBLEM POSSIBLE CAUSE SOLUTION/REASONSNo reading on the am-meter.Clamps are not making a good connection.2-amp charge rate i

Page 11

• 17 •

Page 12

TABLE OF CONTENTSSECTION PAGE1. IMPORTANT SAFETY INSTRUCTIONS 12. PERSONAL PRECAUTIONS 23. PREPARING TO CHARGE 24. CHARGER LOCATION 35

Page 13

• 1 •IMPORTANT: READ AND SAVE THIS SAFETY AND INSTRUCTION MANUAL.IMPORTANT SAFETY INSTRUCTIONS1. SAVE THESE INSTRUCTIONS - The DieHard model 71240 Man

Page 14

• 2 •WARNING – RISK OF EXPLOSIVE GASES.WORKING IN THE VICINITY OF A LEAD-ACID BATTERY IS DANGER-OUS. BATTERIES GENERATE EXPLOSIVE GASES DURING NOR-MAL

Page 15 - 50

• 3 •PREPARING TO CHARGE3. If it is necessary to remove the battery from the vehicle to charge it, al-3.1 ways remove the grounded terminal from the b

Page 16

• 4 •FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN VE-6. HICLEA SPARK NEAR BATTERY MAY CAUSE BATTERY EXPLOSION. TO REDUCE RISK OF A SPARK NEAR BATTE

Page 17

• 5 •FOLLOW THESE STEPS WHEN BATTERY IS OUTSIDE VEHICLE. 7. A SPARK NEAR THE BATTERY MAY CAUSE BATTERY EXPLOSION. TO REDUCE RISK OF A SPARK NEAR BATTE

Page 18

• 6 •BATTERY CHARGING - AC CONNECTIONS8. For all grounded cord-connected battery chargers: 8.1 GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS • –

Page 19

• 7 •Recommended minimum AWG size for extension cords for battery 8.3 chargers:25 50 100 150(7.6) (15.2) (30.5) (45.6)0 2 18 18 18 162 3 18 18 16 143